HLX: Canbelego Copper Drilling Starts
Released
Released
Announcement PDF
ASX Announcement
16 May 2024
CANBELEGO COPPER DRILLING STARTS
Resolution Drilling’s Drill Rig on site at the Western PDIP anomaly at the Canbelego Copper project
Highlights
•
Drill campaign has commenced to test highest priority geophysics anomaly at the Canbelego copper project
•
Up to 3000 m allocated to test a large (625m long) undrilled Induced Polarisation (IP) chargeable anomaly
located west of the Canbelego copper resource1 and considered highly prospective for additional Cobarstyle parallel copper lodes
•
Drilling with Reverse Circulation (RC) pre-collars and diamond core tails is planned to test the strongest part
of the anomaly
•
Initial assay results from drilling are anticipated in late June and further target definition will continue
south along the Rochford Trend at the Bijoux and Cabalero prospects
•
The Company is maintaining its other ‘discovery activities, such as the auger infill program across three
multi-kilometre gold geochemical anomalies at the Company’s Eastern Group Tenements.
Helix Resources Ltd (ASX:HLX, Helix or the Company) is pleased to announce the commencement of a drill
campaign targeting highly prospective IP anomalies at the Company’s Canbelego copper project, located in the
Cobar-Nyngan area of central NSW2. The Canbelego Joint Venture project is located within EL61053, part of Helix’s
Western Group Tenements.
Helix’s Managing Director, Dr Kylie Prendergast commented:
“The new ‘far’ Western Canbelego target is the largest and strongest IP anomaly which we have identified to date.
1 Refer Appendix A for further details on the Mineral Resource Estimate
2 Refer ASX report 8 May 2024
3 The Canbelego Project is a joint venture with Aeris Resources Ltd (ASX:AIS); HLX holds 70% & AIS 30%
BOARD & MANAGEMENT
Chair
Mike Rosenstreich
Managing Director
Kyle Prendergast
Non-Executive Director
Emmanuel Correia
CAPITAL STRUCTURE
Shares on Issue
2,323M
Market Cap.
6.97M
Share Price
$0.003
CONTACT US
helix@helixresources.com.au
Level 13 191 St Georges Terrace
Perth, WA 6000
helixresources.com.au
ASX: HLX
The commencement of a new drilling campaign is always exciting and I am very interested to see what we unearth
by testing this large-scale, chargeable and as-yet undrilled target.
This program is testing for new Cobar-style deposits which often feature as parallel lodes of copper mineralisation,
such as those seen at Metal Acquisition Limited’s large, high-garde CSA copper deposit. Helix believes that the
Canbelego copper deposit is analogous to the CSA copper deposit, with three separate high-grade copper lodes
already identified in drilling to date.
Whilst we wait for the first assays from the Canbelego drilling, expected in late June, we are continuing infill auger
drilling for gold at our Eastern Group Tenements. We plan for a strong stream of news from this highly active
period.”
Figure 1 – Canbelego 3D inversion IP chargeability depth slice at 130mRL (175m below
surface) and outline of anomalous surface copper geochemistry.
2
Canbelego IP Targets
The Company recently completed an induced polarisation (IP) survey northwest of the Canbelego copper deposit
extending the IP coverage north of known mineralised zones at Canbelego4 (Figures 1 and 2). A pole-dipole (PDIP)
array was used for all lines, using 100m receiver dipoles, with 50m dipoles used on the northern most line.
The PDIP survey defined a prominent NNW-trending Western chargeable anomaly with a strike length of 625m,
which is more chargeable and larger than the anomaly associated with the Canbelego Main Lode.
Significantly, this anomaly is outside the previously drilled area, but within the surface copper geochemical
anomaly (Figures 1 and 2). The depth to the top of the chargeable zone is approximately 130m vertical and this
PDIP anomaly represents a compelling drill target.
Figure 2 – Canbelego 3D inversion IP chargeability shells looking down towards the northwest,
showing drilling, the Main Lode MRE block model5, the West Lodes >0.1% Cu mineralisation shells.
Initially three drillholes are proposed to test the new undrilled Western IP anomaly (XXCAN labels).
4 Refer ASX report 8 May 2024
5 Refer Appendix A for further details.
3
COMPETENT PERSON STATEMENT
The information in this report that relates to exploration results, Mineral Resource estimates and geological data
for the Cobar projects is based on information generated and compiled by Mr. Gordon Barnes and Dr. Kylie
Prendergast who are both employees and shareholders of the Company. Mr. Barnes and Dr. Prendergast are
Members of the Australian Institute of Geoscientists. They both have sufficient experience that is relevant to the
styles of mineralisation and types of deposits under consideration and to the activities being undertaken to each
qualify as Competent Person(s) as defined in the 2012 Edition of the “Australasian Code for Reporting of
Exploration Results, Mineral Resources and Ore Reserves”. Mr. Barnes and Dr. Prendergast have consented to the
inclusion of this information in the form and context in which it appears in this report.
This ASX release was authorised by the Board of Directors of Helix Resources Ltd.
HLX
ABN: 27 009 138 738
ASX: HLX
Board of Directors:
Mike Rosenstreich – Chair
Kylie Prendergast – Managing Director
Emmanuel Correia – Non-executive Director
Contact Details:
Helix Resources Limited
Level 4, 225 St Georges Terrace,
Perth, WA, 6000
Company Secretary
Ben Donovan
PO Box 7237
Cloisters Square PO
Perth, WA 6850
Investor Contact:
Mike Rosenstreich
Company Contacts
Email: helix@helixresources.com.au
Web: www.helixresources.com.au
Tel: +61 (0)8 9321 2644
Media Contact:
David Tasker
Chapter One Advisers
Email: dtasker@chapteroneadvisors.com.au
Tel: 0433 112 936
About Helix Resources
Helix Resources is an ASX-listed resources company which is
exploring in the prolific copper producing region of Cobar, NSW.
The Company possesses a sizable ground position across three
tenement groups which are largely untested despite being
located within ~50km of significant copper producing operations.
The strategy is to generate new copper and gold targets on its
large, underexplored ground position and test them through
drilling to make new discoveries.
The western tenement group consists of 30km of contiguous
strike and the Company is advancing a pipeline of wholly owned
copper opportunities, as well as the Canbelego JV Project (70%
owned and operated by Helix and 30% owned by Aeris
Resources) where a Mineral Resource of 32.8kt of contained
copper has been estimated (refer Appendix A). The eastern
tenement group encompasses more than 150km of prospective
strike and includes the 100% owned high-grade CZ copper
project.
4
Appendix A: Canbelego Main Lode Mineral Resource Estimate
A Mineral Resource Estimate for the Canbelego Main Lode was completed by MEC Mining. This was the first
update of the Canbelego resource since the 2010 resource estimate.
The 2023 updated Mineral Resource Estimate for the Canbelego Main Lode is presented in Table 1 below.
Table 1: 2023 Canbelego Main Lode Mineral Resource Estimate (MRE)
MRE Category
Tonnes
Grade (Cu%)
Cu-Metal (t)
Total opencut MRE, ≥240mRL; 0.3 Cu% cut-off grade & underground MRE, <240mRL; 0.8 Cu% cut-off grade
Indicated
340,600
1.65
5,620
Inferred
1,493,700
1.75
26,140
Total: Opencut & Underground
1,830,000
1.74
31,842
Tonnes
Grade (Cu%)
Comprising:
MRE Category
Cu-Metal (t)
Potential opencut MRE, ≥240mRL; 0.3 Cu% cut-off grade
Indicated
99,700
1.28
1,276
Inferred
282,300
1.21
3,416
Total: potential opencut MRE
377,000
1.23
4,637
Potential underground MRE, <240mRL; 0.8 Cu% cut-off grade
Indicated
240,900
1.81
4,360
Inferred
1,211,400
1.88
22,774
1.87
27,171
Total: potential underground MRE
1,453,000
* Numbers may not sum due to rounding
* Numbers are rounded to reflect that they are estimates
* A top-cut grade of Cu 12% was applied to the MRE
* Stated MRE complies with Reasonable prospects of eventual economic extraction
The Mineral Resource Estimate announced on 14 June 2023.
The Company confirms that it is not aware of any new information or data that materially affects the information included in
the relevant market announcement and, in the case of mineral resource estimate, that all material assumptions and technical
parameters underpinning the estimates in the relevant market announcement continue to apply and have not materially
changed.
5
ATTACHMENT 1: JORC Code Table 1
May 2024 – Canbelego IP surveys
Section 1 Sampling Techniques and Data
Criteria
JORC Code explanation
Sampling
techniques
•
•
•
•
Drilling
techniques
•
Nature and quality of sampling (e.g. cut channels,
random chips, or specific specialised industry
standard measurement tools appropriate to the
minerals under investigation, such as down hole
gamma sounds, or handheld XRF instruments, etc.).
These examples should not be taken as limiting the
broad meaning of sampling.
Include reference to measures taken to ensure sample
representivity and the appropriate calibration of
any measurement tools or systems used.
Aspects of the determination of mineralisation that
are Material to the Public Report.
In cases where ‘industry standard’ work has been
done this would be relatively simple (e.g. ‘reverse
circulation drilling was used to obtain 1 m samples
from which 3 kg was pulverised to produce a 30 g
charge for fire assay’). In other cases more
explanation may be required, such as where there is
coarse gold that has inherent sampling problems.
Unusual commodities or mineralisation types (e.g.
submarine nodules) may warrant disclosure of
detailed information.
Drill type (e.g. core, reverse circulation, open- hole
hammer, rotary air blast, auger, Bangka, sonic, etc.)
and details (e.g. core diameter, triple or standard
tube, depth of diamond tails, face-sampling bit or
other type, whether core is oriented and if so, by what
method, etc.).
Commentary
PDIP Survey
• In a pole-dipole IP (PDIP) survey, electrodes are arranged in a triangular configuration
consisting of a current electrode (pole), a potential electrode (dipole), and a remote
electrode (another dipole).
• Measurements are taken by systematically moving the current and potential
electrodes along a survey line while keeping the remote electrode fixed.
• Pole-dipole surveys are designed to provide deeper penetration and are typically used
to investigate larger-scale subsurface features and structures.
• This method is suitable for identifying large chargeability and resistivity anomalies.
• The PDIP survey was completed by Fender Geophysics between 11 April and 30 April
2024.
• Equipment used included a GDD TxIV 9kVA Transmitter and a GDD Rx32 16 channel IP
Receiver.
• Receiving electrodes were standard non-polarising porous pots and transmitter
electrodes were buried metal plates.
• Survey lines were 1.5km long.
• A PDIP array was used for all lines, using 100m receiver dipoles, with the northernmost
line using 50m dipoles.
• The PDIP lines had 16 x 100m receiver channels laid out along the entire 1.5km long
line, apart from the northernmost line which had 33 x 50m receiver channels.
• The transmitter pole electrode was moved along the line at 100m stations.
• All receiver channels were read for every transmitter station resulting in forward and
backward-looking pole-dipole data.
• The remote transmitter electrode was located several kilometres away from the survey
lines.
• The transmit frequency used was 0.125 Hz (2 seconds on-time, 2 seconds off-time).
• No new drilling in this report.
6
Criteria
JORC Code explanation
Drill sample
recovery
•
•
•
Logging
•
•
•
Sub- sampling
techniques
and sample
preparation
•
•
•
•
•
•
Method of recording and assessing core and chip
sample recoveries and results assessed.
Measures taken to maximise sample recovery and
ensure representative nature of the samples.
Whether a relationship exists between sample
recovery and grade and whether sample bias may
have occurred due to preferential loss/gain of
fine/coarse material.
Whether core and chip samples have been
geologically and geotechnically logged to a
level of detail to support appropriate Mineral
Resource estimation, mining studies and
metallurgical studies.
Whether logging is qualitative or quantitative in
nature. Core (or costean, channel, etc.)
photography.
The total length and percentage of the relevant
intersections logged.
If core, whether cut or sawn and whether quarter,
half or all core taken.
If non-core, whether riffled, tube sampled, rotary
split, etc. and whether sampled wet or dry.
For all sample types, the nature, quality and
appropriateness of the sample preparation
technique.
Quality control procedures adopted for all subsampling stages to maximise representivity of
samples.
Measures taken to ensure that the sampling is
representative of the in-situ material collected
including for instance results for field,
duplicate/second-half sampling.
Whether sample sizes are appropriate to the grain
size of the material being sampled.
Commentary
•
No new drilling in this report.
• No new drilling in this report.
• No new drilling in this report.
7
Criteria
JORC Code explanation
Quality of
assay data
and
laboratory
tests
•
•
•
Verification
of sampling
and assaying
Location of
data points
•
•
•
•
•
•
•
Data spacing
and
distribution
•
•
•
Commentary
The nature, quality and appropriateness of the
assaying and laboratory procedures used and
whether the technique is considered partial or total.
For geophysical tools, spectrometers, handheld XRF
instruments, etc., the parameters used in
determining the analysis including instrument make
and model, reading times, calibrations factors
applied and their derivation, etc.
Nature of quality control procedures adopted (e.g.
standards, blanks, duplicates, external laboratory
checks) and whether acceptable levels of accuracy
(i.e. lack of bias) and precision have been
established.
The verification of significant intersections by either
independent or alternative company personnel.
The use of twinned holes.
Documentation of primary data, data entry
procedures, data verification, data storage (physical
and electronic) protocols.
Discuss any adjustment to assay data.
Accuracy and quality of surveys used to locate drill
holes (collar and down-hole surveys), trenches, mine
workings and other locations used in Mineral
Resource estimation.
Specification of the grid system used.
Quality and adequacy of topographic control.
•
•
Refer to Sampling Techniques above for survey specifications.
Field QAQC was completed by Fender Geophysics staff. Post-survey, further QAQC and
data processing, including 2D and 3D inversion modelling was undertaken by Mitre
Geophysics.
•
No new drilling in this report.
•
•
•
The PDIP transmitter and receiver sites were positioned using a Garmin GPS62 GPS (±5m
accuracy).
Grid system is MGA94 Zone 55.
Surface RL data for PDIP sites is collected using GPS and rectified by high-resolution
publicly available digital elevation data (ELVIS 5m data).
Data spacing for reporting of Exploration Results.
Whether the data spacing and distribution is
sufficient to establish the degree of geological and
grade continuity appropriate for the Mineral
Resource and Ore Reserve estimation procedure(s)
and classifications applied.
Whether sample compositing has been applied.
•
•
The survey spacing is considered adequate for an orientation IP.
No new drilling in this report.
8
Criteria
JORC Code explanation
Orientation
of data in
relation to
geological
structure
•
Sample
security
Audits or
reviews
Commentary
•
The orientation IP lines were oriented perpendicular to geological strike.
•
Whether the orientation of sampling achieves
unbiased sampling of possible structures and
the extent to which this is known, considering
the deposit type.
If the relationship between the drilling orientation
and the orientation of key mineralised structures is
considered to have introduced a sampling bias, this
should be assessed and reported if material.
•
The measures taken to ensure sample security.
•
No new samples reported.
•
The results of any audits or reviews of sampling
techniques and data.
•
No additional audits or reviews have been conducted to date.
9
Section 2 Reporting of Exploration Results
(Criteria listed in the preceding section also apply to this section.)
Criteria
Mineral
tenement and
land tenure
status
JORC Code explanation
•
•
Commentary
•
Type, reference name/number, location and ownership
including agreements or material issues with third parties such
as joint ventures, partnerships, overriding royalties, native
title interests, historical sites, wilderness or national park and
environmental settings.
The security of the tenure held at the time of reporting along
with any known impediments to obtaining a licence to
operate in the area.
•
•
Exploration
done by
other parties
•
Geology
•
Deposit type, geological setting and style of mineralisation.
•
Drill hole
Information
•
A summary of all information material to the understanding of
the exploration results including a tabulation of the following
information for all Material drill holes:
o easting and northing of the drill hole collar
o elevation or RL (Reduced Level – elevation above sea level
in metres) of the drill hole collar
o dip and azimuth of the hole
o down hole length and interception depth
o hole length.
If the exclusion of this information is justified on the basis that
the information is not Material and this exclusion does not
detract from the understanding of the report, the Competent
•
•
Acknowledgment and appraisal of exploration by other
parties.
•
•
10
The Company has 20 Exploration Licenses (EL’s) in the Cobar-Nyngan region
of NSW held by its 100% subsidiary company, Oxley Exploration Pty Ltd.
• 19 are held 100% by Oxley Exploration Pty Ltd, a wholly owned
subsidiary of Helix Resources: EL6140, EL6501, EL6739, EL7438,
EL7439, EL7482, EL8433, EL8608, EL8633, EL8710, EL8768, EL8845,
EL8948, EL8703, EL9345, EL9385, EL9386, EL9387, EL9581.
• EL6105 is a joint venture with Aeris Resources Ltd (30%
participating interest) and Oxley Resources Pty Ltd (70%
participating interest and Manager).
Native Title Claim NC2012/001 has been lodged by NTSCORP Ltd on behalf
of the Ngemba, Ngiyampaa, Wangaaypuwan and Wayilwan traditional
owners in the Cobar-Nyngan region which covers the Oxley Exploration Pty
Ltd tenement portfolio.
All tenements are in good standing and there are no known impediments
to operating in this area.
All tenements have been the subject of previous exploration by numerous
companies.
Previous exploration data has been compiled, reviewed and assessed for all
tenements held by the Company.
The tenements are prospective for structurally controlled base metal and
gold deposits.
No new drilling in this report.
Criteria
Data
aggregation
methods
JORC Code explanation
•
•
Relationship
between
mineralisation
widths and
intercept
lengths
•
Diagrams
•
Balanced
reporting
•
Further work
•
•
•
Commentary
Person should clearly explain why this is the case.
In reporting Exploration Results, weighting averaging
techniques, maximum and/or minimum grade truncations
(e.g. cutting of high grades) and cut-off grades are usually
Material and should be stated.
Where aggregate intercepts incorporate short lengths of
high-grade results and longer lengths of low-grade results,
the procedure used for such aggregation should be stated and
some typical examples of such aggregations should be shown
in detail.
These relationships are particularly important in the reporting
of Exploration Results.
If the geometry of the mineralisation with respect to the drill
hole angle is known, its nature should be reported.
If it is not known and only the down hole lengths are reported,
there should be a clear statement to this effect (e.g. ‘down hole
length, true width not known’).
Appropriate maps and sections (with scales) and tabulations of
intercepts should be included for any significant discovery
being reported These should include, but not be limited to a
plan view of drill hole collar locations and appropriate
sectional views.
Where comprehensive reporting of all Exploration Results is
not practicable, representative reporting of both low and high
grades and/or widths should be practiced to avoid misleading
reporting of Exploration Results.
The nature and scale of planned further work (e.g. tests for
lateral extensions or depth extensions or large-scale step-out
drilling).
Diagrams clearly highlighting the areas of possible
extensions, including the main geological interpretations and
future drilling areas, provided this information is not
commercially sensitive.
•
No new assay results in this report.
•
No new drilling in this report.
•
Refer to Figures in this report.
•
The reporting is balanced, and all material information has been disclosed.
•
Confirmed geophysical and geochemical anomalies will be followed-up
with initial RC drilling.
Further auger sampling is in progress in the broader area.
•
11
Share your feedback
Discover