HLX: New Geophysics Outlines Drill Targets at Canbelego
Released
Released
Announcement PDF
ASX Announcement
29 February 2024
NEW GEOPHYSICS OUTLINES DRILL TARGETS AT CANBELEGO
Canbelego Induced Polarisation Trials
Highlights
•
New geophysical survey method identifies two new targets around the Canbelego Main Lode Mineral
Resource 12 – highlighting potential for parallel lodes to increase the scale of the copper deposit
•
Induced Polarisation (IP) survey results at Canbelego have clearly detected the known Mineral Resource effectively testing to a depth of 400 metres (m) for sulphide mineralisation
•
Three discrete IP chargeability anomalies are apparent at a threshold of 30mV/V:
1. Orientation of the IP technique over the Canbelego Main Lode sulphide copper mineralisation produced
a prominent IP chargeable anomaly.
2. New undrilled anomaly (‘Central’) – possible extension and thickening of the Western Lode system.
3. New undrilled anomaly (‘Western’) 600m west of Canbelego Main Lode, detected at 135m depth.
•
IP, as a ‘direct detection’ tool for sulphide mineralisation provides a cost-effective method to test large
areas of prospective structures providing a considerable saving on ‘scout’ drilling.
•
To optimise and offset some planned drilling a Gradient Array IP survey will test a 9km section of the
Rochford Copper Trend, between Canbelego and Caballero and along the large-scale Bijoux copper auger
anomaly in early March.
Helix Resources Ltd (ASX:HLX, Helix or the Company) has successfully trialed the use of an Induced Polarisation
(IP) geophysical survey technique at the Canbelego Main Lode Mineral Resource. The results received clearly
identify the ‘known’ Canbelego copper deposit and highlight two new chargeable IP anomalies that have never
been drilled.
Helix’s Executive Technical Director, Kylie Prendergast commented:
“While it is still early days, the application of IP geophysics is looking like a game-changer for Helix and our
exploration of the Rochford Trend.
Copper mineralisation occurs as ‘sulphide’ minerals in either disseminated, vein stockworks or sometimes massivesulphide textures. The latter can be conductive and to date we have relied on measuring that massive, conductive
feature utilising ‘electromagnetic’ or “EM” survey techniques to identify potential deposits.
However, at Bijoux we intersected copper sulphides at grades well above 1% copper but occurring as veins and
disseminations and hence unlikely to give an EM response.
1 Refer Appendix 1 for further details on the Mineral Resource Estimate.
2 The Canbelego Project is a joint venture with Aeris Resources Ltd (ASX:AIS); HLX holds 70% & AIS 30%)
BOARD & MANAGEMENT
Chair
Mike Rosenstreich
Executive Technical Director
Kyle Prendergast
Non-Executive Director
Emmanuel Correia
CAPITAL STRUCTURE
Share
2,323M
Market Cap.
$7M
Share Price
$0.003
CONTACT US
helix@helixresources.com.au
Level 4 225 St Georges Terrace
Perth, WA 6000
helixresources.com.au
ASX: HLX
IP detects ‘sulphide’ minerals regardless of the textures and we think this technique offers a very cost effective,
direct detection method for finding new copper deposits in the Cobar district.
With our multi-disciplinary approach including pathfinder geochemistry, we think IP can identity quite ‘refined’
drill targets or eliminate targets, which offers significant savings on drilling expenditure and time.
We will now move on to build a fuller picture of the Rochford Trend copper potential by expanding to a wide
coverage ‘gradient array IP’ geophysical survey over known surface copper anomalies and where drillholes have
intersected copper sulphide mineralisation, such as the Cabellero and Bijoux prospects.
This is an exciting development; fast-tracking Helix on a discovery pathway while saving money and optimising our
drill targeting.
Figure 1 – Rochford Trend Canbelego to Bijoux area showing copper geochemistry,
structure and IP survey areas.
2
Introduction
The Company has completed an orientation induced polarisation (IP) survey over the Canbelego copper deposit
and the Bijoux copper prospect. The aim of the survey was to investigate whether IP could detect known
mineralised zones at Canbelego, and whether previously detected electromagnetic (VTEM) anomalies within the
regionally significant Rochford Trend have an associated IP response.
The Canbelego project area falls with EL6105 a joint venture with Aeris Resources Ltd (ASX:AIS); Helix holds 70%
and manages the JV, Aeris 30%. The Bijoux prospect, as with the rest of Helix’s Cobar regional tenements are
100% held by Helix.
At Canbelego the survey consisted of five 1.5km long survey lines over the Main Lode Mineral Resource 3 and
Western Lodes mineralisation. Four of those lines were parallel across the mineralisation spaced at 200m (170m
for the southern line). The fifth line was northeast of the Main Lode across two VTEM anomalies 4. The Bijoux
survey consisted of one 1.5km long line across recently discovered significant oxide and copper sulphide
mineralisation in RC drillholes 5 (Figure 1). A pole-dipole (PDIP) array was used for all lines, using 100m receiver
dipoles.
The PDIP data has been modelled using 2D inversion techniques, and a 3D inversion model for the five Canbelego
PDIP lines. The PDIP results confirm that the Main Lode copper mineralisation at Canbelego is detectable by IP
and therefore a broader scale gradient array IP (GAIP) survey is being planned for the Canbelego to Bijoux
corridor in the Rochford Trend (Figure 1). Further details on the IP survey specifications and data processing are
provided in Attachment 1 (JORC Table 1).
Figure 2 – Canbelego 3D inversion IP chargeability depth slice at 130mRL (175m
below surface).
3 Refer Appendix A for further details
4 Refer ASX report 23 March 2021
5
Refer ASX report 15 January 2024
3
Canbelego IP results
The Canbelego PDIP survey generated high-quality and low noise data and has defined three discrete IP
chargeability anomalies at a threshold of 30mV/V (Figure 2). The 350m long eastern chargeable anomaly
coincides with the known Canbelego Main Lode mineralisation. The top of the chargeable zone is from 125m
vertical, deeper than the observed mineralisation which starts near surface (Figure 3). This is partly due to nonchargeable, or poorly chargeable oxide and transition copper mineralisation near surface, and partly due to the
100m dipole size of survey, which was designed to emphasise deeper, rather than shallow, chargeable anomalies.
The central chargeable anomaly corresponds to the southern end of the Western Lodes, however the 3D
inversion model indicates that the widest part of this anomaly has not been drilled (Figure 3). The western
chargeable anomaly is NNW-trending with approximately 300m of strike length. The depth to the top of the
chargeable zone is approximately 130m vertical. This anomaly is coincident with a farm track with electric fencing
in the south, however interrogation of the data shows no obvious fence effects. Significantly, this anomaly is well
outside of the drilled area at Canbelego and represents a new drill target.
A 3D view of the inverted IP chargeability anomalies is presented in Figure 3. This figure shows that the Main Lode
MRE block model is completely enclosed by the 30mV/V chargeability shell from approximately 125m vertical
depth to beyond 400m vertical depth. Similarly, the depth to the top of 30mV/V shell in central and western
chargeable anomalies is approximately 140m vertical, and both these anomalies have not been drilled previously.
Further refining of these chargeable anomalies will be undertaken after the proposed gradient array IP surveys
(Figure 1) are completed in the next month. This will include quantifying the impact of the electric fence on the
western chargeability anomaly.
Figure 3 – Canbelego 3D inversion IP chargeability shells looking down towards the northwest, showing
drilling, the Main Lode MRE block model, the West Lodes >0.1% Cu mineralisation shells.
4
The inverted 2D resistivity sections show that the Main Lode mineralisation occurs at a clear transition in the
basement between resistive (blue) rocks to the west and less resistive (green/yellow) rocks to the east (Figure 4).
The resistivity appears to be mapping a structure where the copper mineralisation is located, and this structure
remains open to the south into undrilled areas (Figure 4). The resistivity response in the proposed gradient array
IP survey will be important for identifying key structures for future drill targeting.
Figure 4 – Canbelego 2D inverted resistivity sections looking down towards the south, showing drilling, the
Main Lode MRE block model and the West Lodes >0.1% Cu mineralisation shells.
Bijoux IP results
The Company recently discovered significant oxide copper mineralisation near surface at Bijoux, e.g. drill hole
BJRC012 which intersected 36m at 0.99% Cu from 41m, including 6m at 1.99% Cu from 62m, and 3m at 2.14% Cu
from 74m 6. The orientation PDIP line at Bijoux was designed to cross the collar position of BJRC012 so that the IP
chargeability and resistivity response over this mineralisation could be assessed to determine if a broader GAIP
survey would be applicable for exploration targeting.
The Bijoux PDIP line identified conductive cover and a resistive basement, which also has some inherent weak
chargeability. The surficial units comprise shallow clay and sand (<2m deep) over weathered basement rocks,
which are quite conductive (20-40 ohm.m), however it is not expected that this would mask any response from a
chargeable source at depth.
The IP chargeability response at Bijoux is relatively subdued compared to Canbelego. However a subtle, shallow
vertical 6mV/V response extends to surface, coincident with the position of the BJRC012 mineralised intercept, as
6 Refer ASX report 15 January 2024
5
shown in Figure 5. Whilst the IP chargeability response is subtle, it is significant, and based on an assessment of
the PDIP results, a GAIP survey will be completed next month to test the broader Bijoux copper anomaly (Figure
1).
Figure 5 – 2D inverted chargeability PDIP section at Bijoux looking northwest, showing the association
between the BJRC012 drill intercept and subtle, vertical chargeability anomaly.
Next Steps
Two GAIP surveys are planned; the first covering a 16km2 area from north of Canbelego to south of Caballero, and
the second covering a 5km2 area over the Bijoux prospect (Figure 1). A GAIP survey is a cost-effective method
surveying large areas to detect chargeability and resistivity anomalies, however GAIP will not provide a depth
constraint on any identified anomalies. GAIP anomalies will need to be followed-up with PDIP surveys to
accurately define the depth and geometry of the anomalies. Utilisation of GAIP to detect sulphide mineralisation
and then PDIP to better define the target ahead of drilling will fast track drill testing and, optimise the drill success
rate – saving drill metres and hence expenditure.
The GAIP surveys will commence in early March 2024, with the surveys expected to be completed in late-March.
Follow-up PDIP surveys will be undertaken after that to define drill targets.
6
COMPETENT PERSON STATEMENT
The information in this report that relates to exploration results, Mineral Resource estimates and geological data
for the Cobar projects is based on information generated and compiled by Mr. Gordon Barnes and Dr. Kylie
Prendergast who are both employees and shareholders of the Company. Mr. Barnes and Dr. Prendergast are
Members of the Australian Institute of Geoscientists. They both have sufficient experience that is relevant to the
styles of mineralisation and types of deposits under consideration and to the activities being undertaken to each
qualify as Competent Person(s) as defined in the 2012 Edition of the “Australasian Code for Reporting of
Exploration Results, Mineral Resources and Ore Reserves”. Mr. Barnes and Dr. Prendergast have consented to the
inclusion of this information in the form and context in which it appears in this report.
This ASX release was authorised by the Board of Directors of Helix Resources Ltd.
HLX
ABN: 27 009 138 738
ASX: HLX
Board of Directors:
Mike Rosenstreich - Chair
Kylie Prendergast - Executive Technical Director
Emmanuel Correia – Non-executive Director
Contact Details:
Helix Resources Limited
Level 4, 225 St Georges Terrace,
Perth, WA, 6000
Company Secretary
Ben Donovan
PO Box 7237
Cloisters Square PO
Perth, WA 6850
Investor Contact:
Mike Rosenstreich
Company Contacts
Email: helix@helixresources.com.au
Web: www.helixresources.com.au
Tel: +61 (0)8 9321 2644
Media Contact:
David Tasker
Chapter One Advisers
Email: dtasker@chapteroneadvisors.com.au
Tel: 0433 112 936
About Helix Resources
Helix Resources is an ASX-listed resources company which is ‘all-in on copper’ exploration in the prolific copper
producing region of Cobar, NSW.
The strategy is to generate new copper targets on its large, underexplored ground position and test them through
drilling to make new discoveries.
The Company possesses a sizable ground position across three tenement groups which are largely untested
despite being located within ~50km of significant copper producing operations. The western tenements consist of
30km of contiguous strike and the Company is advancing a pipeline of wholly owned copper opportunities, as well
as the Canbelego JV Project (70% owned and operated by Helix and 30% owned by Aeris Resources) where a
Mineral Resource of 32.8kt of contained copper has been estimated (refer Appendix A). The eastern tenement
group encompasses more than 150km of prospective strike and includes the 100% owned high-grade CZ copper
project.
Appendix A: Canbelego Main Lode Mineral Resource Estimate
A Mineral Resource estimate for the Canbelego Main Lode was completed by MEC Mining. This was the first
update of the Canbelego resource since the 2010 resource estimate.
The 2023 updated Mineral Resource Estimate for the Canbelego Main Lode is presented in Table 1 below.
Table 1: 2023 Canbelego Main Lode Mineral Resource Estimate (MRE)
MRE Category
Tonnes
Grade (Cu%)
Cu-Metal (t)
Total opencut MRE, ≥240mRL; 0.3 Cu% cut-off grade & underground MRE, <240mRL; 0.8 Cu% cut-off grade
Indicated
340,600
1.65
5,620
Inferred
1,493,700
1.75
26,140
Total: Opencut & Underground
1,830,000
1.74
31,842
Tonnes
Grade (Cu%)
Comprising:
MRE Category
Cu-Metal (t)
Potential opencut MRE, ≥240mRL; 0.3 Cu% cut-off grade
Indicated
99,700
1.28
1,276
Inferred
282,300
1.21
3,416
Total: potential opencut MRE
377,000
1.23
4,637
Potential underground MRE, <240mRL; 0.8 Cu% cut-off grade
Indicated
240,900
1.81
4,360
Inferred
1,211,400
1.88
22,774
1.87
27,171
Total: potential underground MRE
1,453,000
* Numbers may not sum due to rounding
* Numbers are rounded to reflect that they are estimates
* A top-cut grade of Cu 12% was applied to the MRE
* Stated MRE complies with Reasonable prospects of eventual economic extraction
Helix Resources is not aware of any new information or data that materially affects the Mineral Resource Estimate announced
on 14 June 2023.
8
ATTACHMENT 1: JORC Code Table 1
February 2024 – Canbelego orientation IP survey
Section 1 Sampling Techniques and Data
Criteria
JORC Code explanation
Sampling
techniques
•
•
•
•
Nature and quality of sampling (e.g. cut channels,
random chips, or specific specialised industry
standard measurement tools appropriate to the
minerals under investigation, such as down hole
gamma sounds, or handheld XRF instruments, etc.).
These examples should not be taken as limiting the
broad meaning of sampling.
Include reference to measures taken to ensure sample
representivity and the appropriate calibration of
any measurement tools or systems used.
Aspects of the determination of mineralisation that
are Material to the Public Report.
In cases where ‘industry standard’ work has been
done this would be relatively simple (e.g. ‘reverse
circulation drilling was used to obtain 1 m samples
from which 3 kg was pulverised to produce a 30 g
charge for fire assay’). In other cases more
explanation may be required, such as where there is
coarse gold that has inherent sampling problems.
Unusual commodities or mineralisation types (e.g.
submarine nodules) may warrant disclosure of
detailed information.
Commentary
PDIP Survey
• In a pole-dipole IP (PDIP) survey, electrodes are arranged in a triangular configuration
consisting of a current electrode (pole), a potential electrode (dipole), and a remote
electrode (another dipole).
• Measurements are taken by systematically moving the current and potential
electrodes along a survey line while keeping the remote electrode fixed.
• Pole-dipole surveys are designed to provide deeper penetration and are typically used
to investigate larger-scale subsurface features and structures.
• This method is suitable for identifying large chargeability and resistivity anomalies.
• The PDIP survey was completed by Fender Geophysics between 30 January and 8
February 2024.
• Equipment used included a GDD TxIV 9kVA Transmitter and a GDD Rx32 16 channel IP
Receiver.
• Receiving electrodes were standard non-polarising porous pots and transmitter
electrodes were buried metal plates.
• Survey lines were 1.5km long.
• A PDIP array was used for all lines, using 100m receiver dipoles.
• Each line had 16 x 100m receiver channels laid out along the entire 1.5km long line.
• The transmitter pole electrode was moved along the line at 100m stations.
• All receiver channels were read for every transmitter station resulting in forward and
backward-looking pole-dipole data.
• The remote transmitter electrode was located several kilometres away from the survey
lines.
• The transmit frequency used was 0.125 Hz (2 seconds on-time, 2 seconds off-time).
GAIP Survey
• In a gradient array IP (GAIP) survey, multiple electrodes are placed in a linear array
with equal spacing between them.
• Measurements are typically taken by varying the separation between the source and
receiver electrodes along the linear array.
• The focus is on measuring the gradient of the IP signal, which refers to the rate of
change of the signal with distance. This allows for better detection of subtle variations
in the IP response.
Criteria
JORC Code explanation
Commentary
•
This method is effective in delineating small-scale features and anomalies, making
them suitable for detailed mapping and targeting.
GAIP surveys will commence in early March 2024
•
No new drilling in this report.
•
No new drilling in this report.
•
Drilling
techniques
•
Drill sample
recovery
•
•
•
Logging
•
•
•
Drill type (e.g. core, reverse circulation, open- hole
hammer, rotary air blast, auger, Bangka, sonic, etc.)
and details (e.g. core diameter, triple or standard
tube, depth of diamond tails, face-sampling bit or
other type, whether core is oriented and if so, by what
method, etc.).
Method of recording and assessing core and chip
sample recoveries and results assessed.
Measures taken to maximise sample recovery and
ensure representative nature of the samples.
Whether a relationship exists between sample
recovery and grade and whether sample bias may
have occurred due to preferential loss/gain of
fine/coarse material.
Whether core and chip samples have been
geologically and geotechnically logged to a
level of detail to support appropriate Mineral
Resource estimation, mining studies and
metallurgical studies.
Whether logging is qualitative or quantitative in
nature. Core (or costean, channel, etc.)
photography.
The total length and percentage of the relevant
intersections logged.
• No new drilling in this report.
10
Criteria
JORC Code explanation
Sub- sampling
techniques
and sample
preparation
•
•
•
•
•
•
Quality of
assay data
and
laboratory
tests
•
•
•
Verification
of sampling
and assaying
•
•
•
Commentary
If core, whether cut or sawn and whether quarter,
half or all core taken.
If non-core, whether riffled, tube sampled, rotary
split, etc. and whether sampled wet or dry.
For all sample types, the nature, quality and
appropriateness of the sample preparation
technique.
Quality control procedures adopted for all subsampling stages to maximise representivity of
samples.
Measures taken to ensure that the sampling is
representative of the in-situ material collected
including for instance results for field,
duplicate/second-half sampling.
Whether sample sizes are appropriate to the grain
size of the material being sampled.
• No new drilling in this report.
The nature, quality and appropriateness of the
assaying and laboratory procedures used and
whether the technique is considered partial or total.
For geophysical tools, spectrometers, handheld XRF
instruments, etc., the parameters used in
determining the analysis including instrument make
and model, reading times, calibrations factors
applied and their derivation, etc.
Nature of quality control procedures adopted (e.g.
standards, blanks, duplicates, external laboratory
checks) and whether acceptable levels of accuracy
(i.e. lack of bias) and precision have been
established.
The verification of significant intersections by either
independent or alternative company personnel.
The use of twinned holes.
Documentation of primary data, data entry
procedures, data verification, data storage (physical
and electronic) protocols.
•
•
Refer to Sampling Techniques above for survey specifications.
Field QAQC was completed by Fender Geophysics staff. Post-survey, further QAQC and
data processing, including 2D and 3D inversion modelling was undertaken by Mitre
Geophysics.
•
No new drilling in this report.
11
Criteria
Location of
data points
JORC Code explanation
•
Discuss any adjustment to assay data.
•
Accuracy and quality of surveys used to locate drill
holes (collar and down-hole surveys), trenches, mine
workings and other locations used in Mineral
Resource estimation.
Specification of the grid system used.
Quality and adequacy of topographic control.
•
Data spacing for reporting of Exploration Results.
Whether the data spacing and distribution is
sufficient to establish the degree of geological and
grade continuity appropriate for the Mineral
Resource and Ore Reserve estimation procedure(s)
and classifications applied.
Whether sample compositing has been applied.
Whether the orientation of sampling achieves
unbiased sampling of possible structures and
the extent to which this is known, considering
the deposit type.
If the relationship between the drilling orientation
and the orientation of key mineralised structures is
considered to have introduced a sampling bias, this
should be assessed and reported if material.
•
•
The survey spacing is considered adequate for an orientation IP.
No new drilling in this report.
•
The orientation IP lines were oriented perpendicular to geological strike.
•
The measures taken to ensure sample security.
•
No new samples reported.
•
The results of any audits or reviews of sampling
techniques and data.
•
No additional audits or reviews have been conducted to date.
•
•
Data spacing
and
distribution
Orientation
of data in
relation to
geological
structure
Sample
security
Audits or
reviews
Commentary
•
•
•
•
•
•
•
The PDIP transmitter and receiver sites were positioned using a Garmin GPS62 GPS (±5m
accuracy).
Grid system is MGA94 Zone 55.
Surface RL data for PDIP sites is collected using GPS and rectified by high-resolution
publicly available digital elevation data (ELVIS 5m data).
12
Section 2 Reporting of Exploration Results
(Criteria listed in the preceding section also apply to this section.)
Criteria
Mineral
tenement and
land tenure
status
JORC Code explanation
•
•
Commentary
Type, reference name/number, location and ownership
including agreements or material issues with third parties such
as joint ventures, partnerships, overriding royalties, native
title interests, historical sites, wilderness or national park and
environmental settings.
The security of the tenure held at the time of reporting along
with any known impediments to obtaining a licence to
operate in the area.
•
•
•
Exploration
done by
other parties
•
Geology
•
Deposit type, geological setting and style of mineralisation.
•
Drill hole
Information
•
A summary of all information material to the understanding of
the exploration results including a tabulation of the following
information for all Material drill holes:
o easting and northing of the drill hole collar
o elevation or RL (Reduced Level – elevation above sea level
in metres) of the drill hole collar
o dip and azimuth of the hole
o down hole length and interception depth
o hole length.
If the exclusion of this information is justified on the basis that
the information is not Material and this exclusion does not
detract from the understanding of the report, the Competent
•
Acknowledgment and appraisal of exploration by other
parties.
•
•
•
13
The Company has 20 Exploration Licenses (EL’s) in the Cobar-Nyngan region
of NSW held by its 100% subsidiary company, Oxley Exploration Pty Ltd.
• 19 are held 100% by Oxley Exploration Pty Ltd, a wholly owned
subsidiary of Helix Resources: EL6140, EL6501, EL6739, EL7438,
EL7439, EL7482, EL8433, EL8608, EL8633, EL8710, EL8768, EL8845,
EL8948, EL8703, EL9345, EL9385, EL9386, EL9387, EL9581.
• EL6105 is a joint venture with Aeris Resources Ltd (30%
participating interest) and Oxley Resources Pty Ltd (70%
participating interest and Manager).
Native Title Claim NC2012/001 has been lodged by NTSCORP Ltd on behalf
of the Ngemba, Ngiyampaa, Wangaaypuwan and Wayilwan traditional
owners in the Cobar-Nyngan region which covers the Oxley Exploration Pty
Ltd tenement portfolio.
All tenements are in good standing and there are no known impediments
to operating in this area.
All tenements have been the subject of previous exploration by numerous
companies.
Previous exploration data has been compiled, reviewed and assessed for all
tenements held by the Company.
The tenements are prospective for structurally controlled base metal and
gold deposits.
No new drilling in this report.
Criteria
JORC Code explanation
Data
aggregation
methods
•
•
Relationship
between
mineralisation
widths and
intercept
lengths
•
Diagrams
•
Balanced
reporting
•
Further work
•
•
•
Commentary
Person should clearly explain why this is the case.
In reporting Exploration Results, weighting averaging
techniques, maximum and/or minimum grade truncations
(e.g. cutting of high grades) and cut-off grades are usually
Material and should be stated.
Where aggregate intercepts incorporate short lengths of
high-grade results and longer lengths of low-grade results,
the procedure used for such aggregation should be stated and
some typical examples of such aggregations should be shown
in detail.
These relationships are particularly important in the reporting
of Exploration Results.
If the geometry of the mineralisation with respect to the drill
hole angle is known, its nature should be reported.
If it is not known and only the down hole lengths are reported,
there should be a clear statement to this effect (e.g. ‘down hole
length, true width not known’).
Appropriate maps and sections (with scales) and tabulations of
intercepts should be included for any significant discovery
being reported These should include, but not be limited to a
plan view of drill hole collar locations and appropriate
sectional views.
Where comprehensive reporting of all Exploration Results is
not practicable, representative reporting of both low and high
grades and/or widths should be practiced to avoid misleading
reporting of Exploration Results.
The nature and scale of planned further work (e.g. tests for
lateral extensions or depth extensions or large-scale step-out
drilling).
Diagrams clearly highlighting the areas of possible
extensions, including the main geological interpretations and
future drilling areas, provided this information is not
commercially sensitive.
•
No new assay results in this report.
•
No new drilling in this report.
•
Refer to Figures in this report.
•
The reporting is balanced, and all material information has been disclosed.
•
GAIP surveys are planned which will be followed-up with PDIP surveys over
any defined anomalies to provide a depth constraint.
Further auger sampling is in progress in the broader area.
Confirmed geophysical and geochemical anomalies will be followed-up
with initial RC drilling.
•
•
14
Share your feedback
Discover